The Necessary Standards for Vinyl Flooring in Winter

Winter has arrived, and many vinyl sheet flooring construction projects are planned to be carried out before the Spring Festival. Therefore, the work pressure of engineering management projects is very high, and community owners often stipulate that each construction technology enterprise must ensure product quality issues for analysis of architectural design projects, without considering whether construction safety standards are met.

In order to better obtain the daily work tasks of floor construction personnel, various construction technology enterprises must strictly follow the regulations of PVC floor construction production and processing technology in floor construction management. They cannot blindly follow the trend, shorten the construction period, or neglect the construction quality standards, otherwise the damage caused will be incalculable. Therefore, everyone reminds everyone once again.

The necessary standards for winter construction of PVC flooring

During the ultra-low temperature period, measures should be taken to avoid and avoid construction defects. The reasons are as follows:

 

  1. The ground is not sufficiently dry due to its dampness and coldness;

 

  1. The ground temperature is low, making it difficult for the decorative materials to fully adhere to the ground;

 

  1. Due to the damage of temperature, the dry consolidation rate of Adhesive is relatively slow. In order to avoid being separated from the business of enterprises, it is necessary to use rollers to continuously roll.

Even after construction, it is easy for the bottom to become hard or soft due to nighttime temperature differences or other temperature differences.

 

To avoid sound construction under adverse factors, the following countermeasures should be adopted:

  1. Firstly, accurately measure the ground temperature at the construction site, and no construction will be carried out below 10 ℃;

 

  1. Take corresponding measures to maintain the room temperature above 10 ℃ for about 12 hours before and after construction;

 

  1. If construction is carried out on concrete floors, it is necessary to check whether the floor is dry enough (with a required moisture content of less than 4.5%).

 

  1. After the construction of balanced cement mortar, the compressive strength will be greatly reduced, and it is necessary to check whether the strength is sufficient;

 

  1. The temperature around the entrance and windows is relatively low, and it is necessary to check in advance whether the minimum temperature has been reached, and minimize insulation measures as much as possible.

Weak ground conditions, common psychological problems during ground engineering construction:

 

The drying period in winter is 2-3 times later than in summer (at least an additional drying period of 3-4 weeks is required);

 

Even if the surface layer appears to have dried early, the inner part of the decorative material may still not be completely dry, and there is a risk of moisture exposure after construction;

 

Before construction, store the adhesive and PVC floor in a warm area so that the packaging of the floor decoration materials can be stamped and repaired.